Cooling Tower Services

Our Services

Cooling Tower Maintenance, Repair & Retrofit Services in Singapore

From routine cleaning to full refurbishment and EC fan retrofits, our own engineers keep your cooling towers running efficiently and safely. As a Singapore cooling tower manufacturer since 2006, we service our own towers and towers from other manufacturers.

Cooling tower maintenance service in Singapore

Routine Service & Maintenance

Scheduled Cooling Tower Maintenance

Regular servicing keeps water clean, protects equipment and maintains cooling performance.

Cleaning and Flushing

  • Hot and cold-water basins will be cleaned and flushed.
  • Make-up float valve and strainers will be cleaned and flushed.
  • Fan belt cover internal will be cleaned and maintained.

Fan Maintenance

  • Fan blade angle will be checked for proper air-flow.
  • Fan belts will be re-tensioned and pulleys will be re-aligned.
  • Motor bearings and other movable parts will be checked and greased as necessary.
  • Fan impeller will be inspected for wear and tear.
  • Fan motor running amperes will be checked and measured.

Infill and Louver Maintenance

  • Infills will be washed and flushed with a low-pressure jet machine.
  • Debris stuck at infills/louvers will be cleared, and general flushing of infills and spray fillings will be performed.
  • Cooling tower external housing will be flushed and cleaned.

General Inspection and Maintenance

  • General inspection of cooling tower parts will be conducted.
  • Cold water basin will be refilled.
  • Infills and spray filling will be removed for thorough flushing and cleaning, and then re-set to proper position (once a year).
  • Internal structures and supports will be flushed to remove clogged dirt and debris (once a year).
  • Corroded internal steel structures will be touched up with epoxy paint.
  • Pump gaskets will be checked for leaks.
  • Pump strainer will be dismantled, cleaned, and reinstalled.

Refurbishment & Retrofit

Cooling Tower Repair, Refurbishment & Upgrades

Extend the life of an existing tower instead of replacing it. Our scope covers every major component.

Fans, Motors & Drives

  • Replacement of Fan with SEEMTEK EC Fan
  • Replacement of Fan Blades Assembly including Hub
  • Replacement of Fan Shaft Housing, Shaft and Bearings
  • Replacement of Fan Motor
  • Replacement of V-Belt
  • Replacement of Fan Nettings & Fan Support

Infills & Drift Eliminators

  • Replacement of PVC Infills
  • Replacement of Drift Eliminator Frames and Blades
  • New HDG Drift Eliminator Frame Works

Structure & Basin

  • Epoxy Paint for Internal and External Structures
  • Replacement of Internal Structures
  • Repair of Leaks at FRP Cold Water Basin
  • Replacement of Spring Isolators
  • New HDG Safety Railing & Cage for Existing Ladder

Pumps, Valves & Piping

  • Replacement of Butterfly and Gate Valves
  • Dismantling and Disposal of Existing CWP Pumps
  • Supply and Installation of New Booster Pumps
  • Replacement of Flexible Joints
  • Replacement of Pressure Vessel Tanks

Electrical & Compliance

  • Replacement of Outdoor Power Isolator
  • LEW Certification for Turning On Cooling Towers & Pumps

Transport & Logistics

  • Delivery of new materials and equipment to site
  • Disposal of unwanted materials off-site

Energy Saving

Cooling Tower EC Fan Retrofit with SEEMTEK

As the authorised SEEMTEK dealer and service centre in Singapore, we analyse your tower design and recommend an EC fan upgrade for lower energy use and less maintenance.

  • Airflow and static pressure measured before the retrofit
  • EC axial fan model selected to match your tower
  • Installation, testing and commissioning by our team
  • After-sales service in Singapore

Learn more about cooling tower EC fan retrofits →

SEEMTEK EC fan retrofit on a cooling tower in Singapore

How It Works

From Site Survey to Handover

Site Survey

Our engineers inspect the tower, fans, infills, basin and pumps, and take photos and measurements.

Proposal & Quotation

You receive a clear scope of work with options for repair, refurbishment or upgrade.

Works on Site

We carry out the work with minimal downtime, following safety and permit requirements.

Testing & Handover

The system is tested and commissioned, and you receive a service report.

FAQ

Frequently Asked Questions

What factors contribute to corrosion in cooling towers?

Water quality: High levels of dissolved minerals, such as calcium and magnesium, can increase the corrosiveness of the water. pH levels outside the optimal range can also accelerate corrosion.

How can corrosion in cooling towers be prevented or mitigated?

Water Treatment: Implementing proper water treatment processes, including filtration, chemical treatment, and pH adjustment, can help control corrosion by minimizing the concentration of corrosive agents in the water.

What are some common problems associated with fan blades in cooling towers?

Imbalances in fan blades, caused by uneven material distribution or damage, can result in excessive vibration, which may lead to premature wear of bearings and other components.

How can problems with fan blades in cooling towers be resolved?

Alignment and Balancing: Ensure that fan blades are properly aligned and balanced to prevent vibration and optimize airflow distribution. This may involve adjusting blade angles, tightening fasteners, or using specialized balancing equipment.

Do you service cooling towers from other manufacturers?

Yes. Besides our own towers, we service, refurbish and retrofit cooling towers from other manufacturers, including replacement of infills, drift eliminators, fans and internal structures.

Need Cooling Tower Maintenance or Repair?

Our engineers will visit your site, check your cooling towers and recommend the right service or upgrade.